Fire door safety and compliance – A practical guide for blocks of flats.

Fire doors importantly hold back smoke and fire long enough for residents to get out.
Since January 2023, every residential block of flats in England has legal duties for fire doors, with stricter checks where the building is above 11 metres.
This guide explains what the fire door regulations require in blocks of flats, with a focus on buildings between 11 and 18 metres.
In brief:
- Every block of flats must give residents fire door information at least once a year.
- Above 11 metres, flat entrance doors must be checked every 12 months and communal fire doors every 3 months, with records kept.
- Getting it wrong is a criminal offence. A good building manager keeps the checks, records and repairs on track.
1. Fire door regulations: which rules apply to your building
- The Regulatory Reform (Fire Safety) Order 2005 (the Fire Safety Order). The foundation. It requires a fire risk assessment and suitable fire precautions in the common parts of every block of flats.
- The Fire Safety Act 2021. It confirms that the Order covers a building’s structure, external walls, and all doors between the flats and the common parts, including flat entrance doors.
- The Fire Safety (England) Regulations 2022. In force since 23 January 2023. Regulation 10 sets out the fire door duties, which depend on the building’s height.
The duties sit with the Responsible Person. That is usually the freeholder or residents’ management company, or it may be the appointed managing agent for the building.
| Building Type | What Regulation 10 asks |
| Two or more flats, any height | Give residents information about fire doors every year, and to new residents soon after they move in |
| Top storey above 11 metres (typically 5 storeys or more) | All of the above, plus checks of flat entrance doors every 12 months and communal fire doors every 3 months |
| 18 metres or more, or seven storeys or more | All of the above, plus the further duties for high-rise and higher-risk buildings, including registration with the Building Safety Regulator |
Height is measured to the floor of the top storey, not the roof. If you are not sure which side of 11 metres your building sits, ask your fire risk assessor to confirm it in writing.
GOOD TO KNOW
For this law, flat entrance doors count as part of the common parts.
The Responsible Person must check them, even though the door usually belongs to the flat.
2. Fire door checks: what, how often, and how to record them
These routine checks are a legal requirement only in buildings whose top storey is above 11 metres. In those buildings, Regulation 10 sets two timetables.
- Flat entrance doors (above 11 metres): at least every 12 months. The duty is to use “best endeavours”. You need to get into each flat, because the door is checked from both sides.
- Communal fire doors (above 11 metres): at least every 3 months. This covers stair and lobby doors, corridor doors, and doors to meter, electrical and service cupboards. There is no best endeavours here: the check must happen.
Every check must confirm that the self-closer shuts the door fully into its frame.
What “best endeavours” means in practice
Residents cannot always be home, and the law accepts that. The government’s guidance suggests offering a range of times so residents can be present.
In our experience, that means:
- At least two weeks’ notice, and a reminder the day before
- A second slot, or the option to leave keys
- A written record of every attempt and every refusal
- A door that is missed twice in a row gets its own appointment
Regulation 10 also requires a record of the steps taken over each 12-month period, including where access was refused. Where a resident persistently refuses, the guidance says legal action may need to be considered.
Who can carry out the checks
The checks are visual: no tools, no specialist accreditation. The government’s guidance says managing agents, caretakers and maintenance staff can do them with appropriate instruction. The person checking needs to know what to look for, and the Responsible Person needs evidence they were shown.
These routine checks do not replace a fire door inspection by a specialist, which is usually done alongside the fire risk assessment.
GOOD TO KNOW
The government’s fire door guidance is issued under Article 50 of the Fire Safety Order.
Since October 2023, failing to follow Article 50 guidance can be used in court as evidence that the law was broken
3. Fire door information for residents: a duty at every height
This part applies to every block with two or more flats and shared escape routes, whatever its height. Residents must be told three things:
- Keep fire doors shut when not in use
- Do not tamper with self-closers, and do not let guests do so
- Report any fault or damage straight away
This must go to all residents at least every 12 months, and to new residents as soon as reasonably practicable after they move in. Tenants count as residents, not just leaseholders. A short annual letter, sent alongside the building’s fire safety instructions, does the job, provided someone records when it went out.
The guidance also says a resident who wants to change or alter their front door should do so with the Responsible Person’s knowledge and agreement. A new front door chosen for its looks can quietly undo the fire protection of the whole landing.
4. What a proper fire door check looks at
On each door, the person checking should look at:
- The self-closer. Open the door fully and let go, then open it to about 15 degrees and let go. Both times it should close fully into the frame, latch and all.
- Seals and strips. Intumescent strips and smoke seals should run all the way round, be undamaged and not be painted over.
- Gaps. No light showing around the edges. The acceptable gap depends on the door’s fire specification, so check it against the door’s certification. Government guidance treats more than 4mm as too large in most cases, apart from the bottom of the door.
- Hinges and ironmongery. No missing or loose screws, no damaged locks.
- The door itself. No splits, holes, warping or unrepaired damage, and any glazing intact.
- Letterboxes and spy holes. Closed, working and suitable for a fire door.
- Has the door been replaced or changed without anyone confirming its fire rating?
- No door held open with a wedge or a fire extinguisher.
For meter and electrical cupboards, the responsible person must check that the door is either self-closing or kept locked.
GOOD TO KNOW
A check is only finished when the problems are fixed. Repairs to any fire door, communal or flat, must be done by a competent contractor as soon as reasonably practicable. The lease decides who pays.
5. The risks of fire door non-compliance
The first risk is the obvious one: a fire door that doesn’t close lets smoke onto the stairs everyone else needs to escape by. The rest follows from that.
Criminal liability. A breach of the Regulations is a criminal offence if it puts someone at risk of death or serious injury in a fire. Under the Fire Safety Order, the most serious offences carry an unlimited fine and up to two years in prison. Directors of a freehold or management company can be pursued personally in some cases.
Enforcement. The fire service can audit a building, serve an enforcement notice setting out works and a deadline, and in serious cases restrict use of the premises. An enforcement notice is a public record, and the works it requires still have to be paid for.
It has happened in London.
- In 2011, a managing agent was fined £100,000 for breaches at a block in Paddington, including fire doors that were not self-closing; the freeholder was fined £33,000.
- In 2020, a property company was fined £20,000, plus £10,000 costs, after a fire in a four-storey block in Palmers Green where flat entrances lacked fire doors and self-closers.
Beyond fines and legal costs, compliance gaps often surface at the worst moment: when a flat is being sold, and the buyer’s solicitor asks for fire safety records, or after an incident, when the building insurer asks what was checked and when. Missing paperwork turns a routine question into a delay or a dispute.
Leaseholder trust. Residents are paying for the building to be looked after through the service charge. A missed check is hard to explain once something has gone wrong.
6. Why your building manager matters for fire door compliance
The law is clear about what has to happen. Whether it does happen comes down to the person who runs your building week to week. A check every three months and a full round of flats every year is a routine, and routines slip unless someone owns them.
A good building manager should be able to show you:
- When each flat door and communal door was last checked, and when the next check is due.
- The letters, reminders and alternative slots offered, and a note of every refused or missed visit.
- Doors not reached last time are first on the list next time, not quietly carried over.
- Defects logged, leaseholders told in writing what needs fixing and by when, and the job chased until it is done.
- The annual resident letter. Sent, dated and on file, with a process for new residents.
- Door check results passed to the fire risk assessor, so the next assessment does not say “no access”.
If you asked your managing agent for these today, how quickly could they produce them?
At M2, fire door checks are built into our building management visits.
We visually check communal fire doors for any visible damage or defects during our monthly building inspections. We also carry out annual visual fire door inspections, or arrange a specialist fire door inspector where required. Residents receive a written report after each visit
It is not complicated, but it must be done the same way every time.
7. Fire door compliance checklist for freeholders and directors
☐ We know whether our building’s top storey is above 11 metres, and it is confirmed in writing
☐ We have a current fire risk assessment, and we have acted on its findings
☐ Above 11 metres, every flat entrance door has been checked in the last 12 months, or we have a record of the attempts
☐ Above 11 metres, every communal fire door has been checked in the last 3 months
☐ Self-closers were tested on every door checked
☐ Defects found are logged, with a date to put them right
☐ All residents received the fire door information this year, and new residents get it when they move in
☐ We could hand all of this to the fire service tomorrow

Not sure where your building stands?
If you could not tick every box above, we are happy to take a look. We can review your current fire door records and tell you plainly what is missing.
Get in touch with the M2 team at hello@m2property.com or on +44 (0)20 7043 8431.